Fire Protection

fireman fire


What SANS 10400: Part T 
– Fire Protection Says

Nobody wants to see their house or business premises go up in flames. This is why there are very strict Regulations when it comes to fire safety and protection against fire in any building in South Africa.

What the Act Says

Essentially the legislation is concerned quite simply with the need for all buildings to be designed, constructed and equipped so that in the event of fire:

  1. the occupants or people using the building will be protected – including persons with disabilities;
  2. the spread and intensity of any fire within buildings, and the spread of fire to any other buildings, will be minimized;
  3. sufficient stability will be retained to ensure that such building will not endanger any other building: provided that in the case of any multi-storey building, no major failure of the structural system shall occur;
  4. the generation and spread of smoke will be minimized or controlled to the greatest extent reasonably practicable; and
  5. adequate means of access, and equipment for detecting, fighting, controlling and extinguishing such fire, is provided.

The requirements of the Act will be deemed to have been satisfied if the design, construction and equipment of buildings complies with SANS 10400 Part T and satisfies the local authority.

The Act also specifies several offences that owners of buildings need to avoid, including the need for fire extinguishers that comply with SANS 10105. Also, if people do anything to obstruct escape routes in buildings, they will be guilty of an offense.

What the Standard Says

The regulations for Fire Protection are contained in a 91 page document published by the SABS, SANS 10400: Part T Fire Protection. Much of the information is the same as that published in the 1990 version of the Standard that you can download from this site.

SANS 10400 Part T is broken down into several parts:

Requirements

The bulk of the Standard is made up of a vast number of different “requirements” that relate not only to dwelling houses, but to every other possible type of building, from hospitals to parking garages.

The requirements for effective fire protection include:

Safety Distances

Although there are other provisions, including the classification of the type of external wall, the table below may be used to establish safety distances where walls do not contain windows or other openings. For ordinary “dwelling houses” where the area of elevation facing any boundary is not more than 7,5 m2, such safety distance may be reduced to 0,5 m.

Fire Resistance

There are several tables (five in all) that indicate requirements for compliance with “Presumed fire resistance of building materials and components”.

This table shows what is required for “structural walls”.

This table shows what is required for “non-structural walls and partitions”.

Rational Designs

The design requirements include the need for a competent person to ensure that the level of fire safety is adequate. This is particularly important in large and public buildings.

This drawing shows the basic fire safety engineering process.

>

Refuse Disposal