Retaining Walls
Picture Above: A retaining wall constructed from specially designed, interlocking blocks
The Implications of Building Retaining Walls
Part K of SANS 10400, Walls in the National Building Regulations (NBR) covers the structural strength and stability of all walls, including those that form part of a house or other building, and both garden and boundary walls.
They also deal with retaining walls which, by definition are intended to “resist the lateral displacement of materials”. If the wall is not designed the right way, it simply won’t resist the pressure of soil or other materials pushing against it, and it might collapse injuring or even killing people. It is for this reason that it is essential for all retaining walls to be designed by a competent person, preferably an engineer, and for plans to be drawn up and submitted to the relevant local authority for approval before building begins.
Over the years we’ve had numerous queries from visitors to this site regarding retaining walls, many homeowners wanting to know whether plans are required.
The only walls you may be build without plans are those that are considered, by the National Building Regulations to be minor building work. Specifically, Part A of SANS 10400, General Principles and Requirements says “any free-standing wall constructed of masonry, concrete, steel, aluminium or timber or any wire fence where such wall or fence does not exceed 1,8 m in height at any point above ground level and does not retain soil,” is regarded as minor building work.
Even though plans are not required for minor building work, it is essential that minor building work complies with the NBR, and you should notify the local authority of your intention to build the wall.
All retaining walls require plans that are approved, and they must be designed by a competent person or build it in accordance with the SABS “deemed to satisfy” rules that are laid out in Part K 4.2.4 Free-standing boundary, garden and retaining walls.

Freestanding retaining walls must be designed and built so that:
- the height of any fill retained by the wall does not exceed the values given in he table below, provided, however, that where x (see figure above) exceeds 0,3 m, the height retained shall be reduced by the difference between x and 0,3 m
- piers, where required in terms of the table below, project on the opposite side of the wall to the fill that is being retained
- control joints are located at intervals that do not exceed 10 m
- no surcharge of fill is placed within a distance equal to the height of the amount of fill being retained, and
- subsoil drainage is provided behind the wall by weepholes formed by building into the waIl, and 50 mm diameter plastic pipes, with the non-exposed end covered with geofabric, at a height that does not exceed 300 mm above the lower ground level, and at centres that do not exceed 1,5 m.

Note that the specifications for garden walls that do not retain earth are different.
“The term ‘minor building work’ was intended to cover certain building work which, because of either its nature or magnitude (or both), was such that it would not be necessary to submit full plans or, in certain cases, where no plans or any other documents would be required.” South African National Building Regulations
What Happens When Retaining Walls are not Built in Accordance With the Building Regulations

Incorrectly built retaining walls can be downright dangerous. Just a couple of months ago an adult and six children were injured when a retaining walls collapsed on them in Quarry Heights, Durban. At the time, the children and several adults were helping Busisiwe Shabane backfill a retaining wall with sand and rubble to create an area that was level with her house. Two of the children were trapped under the wall.
According to Shanbane’s husband, Caphius, they were trying to strengthen the wall which appeared to be about to collapse. He said they were afraid that if the wall collapsed, the house would then collapse. He said they had used tyres, but these had been dislodged by heavy rain. They had also built two retaining walls using hollow cement blocks. When these began to crack and show signs of falling, they broke one down and rebuilt it.
The wall was apparently six blocks high, which would have made the wall about 1,2 m high. Clearly it was not built according to the NBR, and there were certainly no approved plans. Thankfully no-one was killed, but two weeks ago 18 people died and three were injured when a retaining wall collapsed on a shack in China’s Shandong Province. This collapse was also caused by heavy rain.
Properly Built Retaining Walls
Although to the layperson low retaining walls might appear to be simple structures, the risks of badly built walls are acknowledged by engineers. When an engineer designs a retaining wall he or she will evaluate the soil and any rocks that are behind or below where the wall is to be built. They will also determine the best material for backfilling the wall and design drainage so that rain does not cause collapse.
I can’t visualise the area so can’t really judge. But it’s up to the two of you to decide what is fair. If it is a retaining wall you’ll need plans.
Your neighbour should have had approved plans to build the garage. The council might allow a retaining wall to be incorporated, but an engineer would have had to be involved. Contact the council and ask them to investigate. Apart from anything else, in most municipalities (other than Cape Town) require neighbours’ consent for you to build on a boundary.
Since I am at a higher level than my neighbour there is a retaining wall between our erven. The neighbour has erected a garage, a proper building, using the retaining wall as one wall of his new garage. He raised the height of the wall in the process. On my side the height was approximately 1 m, and about two meters on his side. I think that one cannot build on a retaining wall. Is this true?
hi,
I have bank approximately 1.8m in height within my property. My neighbour and I have decided to put up a boundary-wall collectively. The problem is my neighbour is prepared to pay 50% only for the wall up to my property height and wants me to pay fully for the reminder of the wall.
is this fair ?
The National Building Regulations has a list of minor building works that do not require plans. In terms of walls, it states: “any freestanding wall built with masonry, concrete, steel, aluminum, or timber or any wire fence that does not exceed 1,8 m in height at any point above ground level and does not retain soil” … so yes you do. However the local authority has the right to waive the need for plans if they consider them unnecessary. So you will need to contact them.
Hi,
We Would like to build a retaining wall of about 1m in height to level out the garden. Do we need to submit plans for this?
NHBRC does not have laws! Their manuals provide guidelines for good building practise. I doubt there is anything that has guidelines to prevent hairline cracks, because these aren’t structural cracks. There is nothing related to this in the building regs.
Balustrades are not required for walls of any sort. However it seems obvious that this is a public safety issue. There may be some sort of legal requirement but not in the NBR.
Thank you for your advise Penny, i will look into it through council and NHBRC to make sure i the right advice on how to go forward.
I would also like some other advise as i have combed through hundreds of pages and articles concerning the chasing of walls and screeds for electrical conduits and its just plastered over with no mesh wire to hold the plaster all together. with time this forms hair line cracks that never go away. Is there any Building regulation or NHBRC law holding the builder/developer responsible to have this done to prevent these hairline cracks that form along plumbing and electrical conduits?
I think you probably do have a claim against the developer because all walls over 1,8 m must have approved plans. You could probably claim against the managing agents as well.
Hi Penny,
The “boundary wall” of approximate height 2.1m (constructed with 200mm hollow block) in our complex has come down due to the recent storms. No plans were submitted by the developer. The insurance has rejected the claim on the basis that the boundary wall should have been constructed as a retaining wall (it is retain around 1.5m of road reserve soil) hence was not constructed to the NBR specifications. The complex is around 6.5 years old. Do we have a claim against the Developer and should he reconstruct the wall at his cost? If not, what other legal routes can we explore as owners, who purchased their units from managing agents without the knowledge of the developers construction methods actions?
The best would be to come to a plan that is mutually acceptable. But in the event of a dispute, I would hold her responsible.
SANS 10400-A mentions retaining walls in the context of minor building work (which is the only building work that does NOT require plans): “any free-standing wall constructed of masonry, concrete, steel, aluminium or timber or any wire fence where such wall or fence does not exceed 1,8 m in height at any point above ground level and does not retain soil. This clearly indicates that any wall that retains soil is NOT regarded as minor building work and therefore requires plans. However the Council does have the authority to waive the need for plans.
SANS 10400-K (2011), Walls has comprehensive guidelines for retaining walls that vary according to height.
If you are saying that the wall has been built so your neighbour gets extra land you have a case against the council. You should also report the construction company or whoever is doing the building – I’m just sure who to. This article might be of some help. It gives a number for the legal aid board. They might be able to help.
First of all Ricky there are not “so many variations in the law”! If this is what so-called retaining wall companies are telling you:
1) Ask for a reference that gives this specification in the regulations/standards. If you are referring to specialised retaining blocks (e.g. Terraforce or Loffelstein), these companies have their own engineer’s recommendations and certainly these two companies have there own approved systems. This would make sense in terms of the 1,2 m or 65 deg spec they have quoted to you. Also they can be built on gravel.
2) Since the ultimate decision of whether plans must be submitted lies with the local authority, contact them to see if this specification is in line with their needs.
If you are referring to ordinary hollow blocks:
SANS 10400-A mentions retaining walls in the context of minor building work (which is the only building work that does NOT require plans): “any free-standing wall constructed of masonry, concrete, steel, aluminium or timber or any wire fence where such wall or fence does not exceed 1,8 m in height at any point above ground level and does not retain soil. This clearly indicates that any wall that retains soil is NOT regarded as minor building work and therefore requires plans. However the Council does have the authority to waive the need for plans, which is why I suggest you contact them.
SANS 10400-K (2011), Walls has comprehensive guidelines for retaining walls. “Gravel foundations” are not mentioned in this Standard! However there is no detail on foundations required, and very little information in the Standard that specifically covers foundations. Nevertheless building any wall from “hollow blocks” requires a solid concrete foundation and the only drawing of a retaining wall in Part K indicates exactly this – a concrete “strip footing”.
There is also a table that gives specs for retaining walls built from “hollow units”. The angle of the wall is not specified! It gives nominal wall thickness of 140 mm – 190 mm – 190 mm; all are single-leaf walls. Maximum heights 1,1 m – 1,1 m – 1,4 m. Nominal pier dimensions (overall depth x width) should be 600 x 300 mm – 600 x 300 mm – 800 x 400 mm and the maximum centre to centre for spacing of the piers should be 1,8 m – 2,5 m – 2,6 m.
NB The standard does not cover specialist retaining wall systems. There may be another SANS that does, but it is not part of the NBR (SANS 10400).
No you certainly don’t have to allow it.
Hi, my property has been halved and a developer needs to build a retaining wall about 2 meters in height along a boundary. They want to come 2 meters into my property as a chamfer on my property is needed to build the wall.
If this happens, I lose trees that would assist screening their development from my house.
In addition, my driveway would then run along the wall, on the back-filled chamfer area.
Do I have to allow this? Can they not build the wall 2 meters into their property?
This is what confuses me, i have contacted to retaining wall companies and they say that no engineered plans are required for walls under 1,2m or less than 65degree, they say it can be build from hollow blocks with a gravel foundation. why are there so many variations in the law?
I suggest you contact Terraforce. Their engineers will know exactly what you can and can’t do. However, ALL retaining walls required plans.
All retaining walls must have approved plans – so contact the local authority and ask them to investigate as a matter of urgency.
All retaining walls require plans – for obvious reasons
If the water drains onto your neighbour’s property then it is a contravention of the NBR – and a very common one. I have written a lot about this on this site.
Hi Good Day
I am currently building a house through a developer, and the ground level of the property is very sloped. I want to raise the ground level by about 500-600mm and my developer is refusing to do anything as engineers plans to build a retaining wall with in my boundary wall need to be done up. was is the maximum height of retaining wall that can be build with out an engineers plans? in all honesty from everything i have read you are able to build a wall up to 1m high with no piers as long as it is collar jointed 290mm thick and has 50mm weep holes. is it really necessary to get a engineers plans to build a 6-7 course triple leaf wall practically against my boundary wall?
Hi
We have just had a retaining wall built by a qualified engineer.
They put a drainage system into the wall to allow ground water to drain through.
My neighbor is saying that the pipes which allow this water to drain are illegal. Is this true?
Good evening,
We are beneficiaries of a RDP house for 3 months now. 6 metres from our backdoor stands a house erected on a almost 3 metres high sandhill which retains a lot of water and which deals heavily from the soil especially after rainy days. The soil also break away from the house on the hill when it rains. Anytime we dig a whole to erect a pole for wire fencing we bare dig half a metre and the hole fills up with water in no time. After much effort and quarrel with the municipality and the construction company someone finally decided that this is indeed a very dangerous situation in need of a retaining wall which should have been erected in the first place before either house were build. Let me just mention that according to both plans received from the land surveyors and the municipal building offices 5 of the 6metres between these two houses belongs to us. The same construction company that built the houses got the job to build the wall. The decided to erect the wall only at me and my neighbors houses (adjoined) because the hills (soil) are at its highest there, the highest point being behind my house. They are taking all kinds of shortcuts to not have to spend much money. They decided to dig the foundation for the wall 200m and then another 300m but the deeper they dug the more water seeped from the soil so the order was given to dig another 300m deeper but the water got even more they then decided to fill it up again to only 300m as the depth the dug was filled to the brim with seepage water and buying that much concrete would be too expensive. The wouldn’t hire a jetvac truck or something similar to drain the water and instead ordered workers to use cut 2litre coke bottles and buckets to drain the water at which they failed badly. Everything was done in water from the steel rods to the concrete to the 1st 2rows of bricks (190(size) cement blocks). From the start we asked whether pipes (sigpype) would be put in place to assist with draining water from the soil they refused. The wall is now 6blocks high about 3metres then takes a step down to 5 and then down to 4blocks. It’s a single layered wall with a few iron rods and building wire here and there and the soil is still higher than the wall which both my neighbor and I complained about as the wall needs to be lifted at least 2more rows.they started filling up behind the wall almost to its height with more soil as they didn’t want to buy concrete. They planted poles (olie pale) behind the wall and is planning to erect a wire fence in the soil. This is what they are doing after they originally promised a double re-inforced concrete wall which would be able to hold the earth and stop the house from collapsing and falling 3metres and landing on top of our house. Furthermore there excavations took 2 or more metres of our 5metre backyard as whatever land is behind the fenced wall would automatically belong to the house behind the fence which I wouldn’t mind if it was given to me at the front where fence was order to be pushed back 4metres from the street as the sidewalk is apparently to small at 2.7metres which applies only to my neighbor and me one other person the rest of the street gets to fence their yards at 1.5metres from the street. Can someone please advise on whether this is lawful because we really feel like we are being robbed and bullied. We also feel like we are losing land from our plot that was approved for us and subsidized to us by the state as payment for their negligence. I have photos and videos of house that could fall and of different stages of the construction of the wall and the seepage water. They did put pieces af pipe in the wall which by now is blocked by the soil fill but they didn’t put any pipes to lead the water to a drainage system or the street if water does ever come through those little pieces of pipe it wil lie dormant cause puddles everywhere including the backdoor. That water smells bad as it is said to come from the graveyard which is on higher ground about 20 or 30metres away. Please please advise as we do not understand how such things can be approved and get the go ahead. Today some or other municipal lady told us we should count ourselves lucky we are getting a wall for free like they are doing us a favor and not like they are doing disaster management after the fact as the wall should have built before our house was or better yet they shouldn’t have build a house in such a dangerous place.