stairway

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *

138 Comments

  1. Must steps on a tiled staircase be level or can they be at a severe slant ? We recently had a staircase retiled in our office complex and the tiler was told to lay tiles on steps and landing at a severe slant, apparently to assist rain water to flow off quicker.

  2. Technically Gordon, if the stairs have not been built according to plan, the council has every right to demand that they are fixed before they give you an occupancy certificate.

  3. Hi

    The staircase in question is already built. I see that the risers are to be 200MM in height at the most.
    The risers on this staircase are anywhere between 221MM and 250MM. They are all different heights. Is this staircase a problem and will the council occupancy going to be affected by this. Does it need to be corrected according to the regulations before an inspection.

    Thanks,

  4. There is no building regulation against having pot plants on a stairway, but the health and safety regulations might come into play if the stairway is open to the public. The Occupational Health and Safety Act specifies how workplaces and public places must be kept safe.

  5. May there be any pot plants on the stairway – floor to floor

  6. Arno the regulations are really not that prescriptive. Manufacturers’ specifications should state that the product is SABS approved and if it is a fire retardant, it should state this as well. I suggest you call the SABS and/or a couple of major paint manufacturers. You might also contact your local fire department.

  7. Hi, I wan’t to find out what the fire prevention regulations is on the paint of inside steel stairs of a building that is used as a fire escape. Is there a specific paint that needs to be used that is fire retardant and can you maybe send me the regulation if so?

  8. Louis, As far as I know there is no specific standard for steel stairs – and the NBR do not differentiate between materials used to build stairs.
    I think the landing should be at least the width of the door – so it could be less than your dimensions.
    Since you specialize in steelwork (I presume from the name), I am sure you know a lot more about the subject than I do!

  9. Hi,
    Did the regulation on steel stairs change?

    1. Landing out the door min 1.5×1.2. Unless the door is see through.
    2. a flight of stairs should not be more than 3m with out a landing inbetween.
    3. In between flights should nou be closed and not lipped up at the bottom and down at the top.

    Please advise.

    Louis

  10. As far as I know, in terms of the NBR, railings and balustrades need to be at least 1 m high, and should not have openings any greater than 100 mm diameter. Other than that I don’t think there are specific requirements.
    The NHBRC manual I have states in its guidelines that freestanding balustrade walls should have a thickness of not less than the height of the wall above the base divided by a measurement based on the units used to build the wall. e.g. 5 mm for a solid unit (no dpc). It also says that if the balustrades have returns or are fixed to columns at centres not more than 3,5 m, the thickness must be 110 mm for solid units and 140 mm for hollow units. Returns must continue for at least 0,75 m from the outside face of the walls.
    But remember that these are recommendations and any “competent person”, e.g. an architect, will be able to design the balustrade taking all elements of the structure into account.

  11. Catherine says:

    I would like to know what the legal specification is for the measurement between infills of a balustrade and from a wall to a balustrade. What is the legal space allowed?
    Thank you

  12. Why not just build a step between the patio and the ground? It’ll probably look better too. YOu could probably do it yourself using bricks loose laid and dug into the earth – then backfill between the bricks and the patio and top with paving bricks or slabs. You don’t have to do it all the way along the patio – just a couple of metres.

  13. Craig Lubbe says:

    Thanks for the response.
    Yes I currently have to step up 42cm to get onto the patio.
    I think I’ll see if the ground can’t be back-filled some more so as to lower change in height to around 200mm.

  14. The National Building Regulations say that step risers should not be steeper than 200 mm. So you should have a step between the patio and the ground (because at the moment it sounds as if you have to step up or down 400 mm). It doesn’t sound as if railings are an issue.

  15. Craig Lubbe says:

    What about a patio? We have one but the drop between that and the ground is just over 40cm or so.. It doesn’t feel safe as a step height with no railings. What governs this?

  16. Hazel if you are convinced that the stairs are dangerous, I suggest you call your local authority and ask them for advice.

  17. Hazel Johnstone says:

    Thanks for the response, Yes it is metal. I review M of SANS 10400, however it does not give me any angle of the incline stairs. Can you furhter elaborate on the angle of the stairs.

  18. Hazel I presume your stairs are METAL. The NBRs don’t distinguish between different materials, but the SANS (deemed-to-satisy requirements) do give guidelines in terms of the height of risers. This has a direct effect on the incline. I have added info to this section. I hope it will be helpful. If there is still something you need to know, please post another query.

  19. There are no specific laws that relate to businesses (vs homes) and the regs relate to stairways in general – i.e. in/out no difference. If you want to see what SANS 10400 Part M Stairways says, you can buy the standard from the SABS, or pop into your nearest office and you can read the standard in their library.

  20. You wouldn’t normally need a fire escape staircase for a mezzanine. More importantly, the area needs to be “fit for purpose for which it is intended”. In terms of a mezzanine floor, I think there needs to be 2,1 m above and below the floor. Also only a certain number of people are permitted to “occupy” a certain sized space.

  21. Dillon Freeman says:

    Good day,

    I would like to know if a fire escape staircase is required to be constructed for a 100m2 concrete mezzanine floor? The mezzanine floor is to be changed into a small office for about 5 to 10 people. The mezzanine level forms a first floor of an exisitng single storey building and has an internal staircase already with fire extinguishers fitted to walls. Can you help?

    Regards,

    Dillon

  22. Hazel Johnstone says:

    if there is specific legislation requriements for stairways for a company be it internal or outdoor, can you please let me know how i can find the written legislation requirements or regulations

  23. Hazel Johnstone says:

    I am wrkingfor a company in South Africa. My question is that we have mental stairways, however it incline very high coming down the stairs, is there a specific specfication for the stairway as per legislation requirements, please advice

  24. It needs to be erected about 850mm – 1m above the stairs and should be securely fixed so that it doesn’t form an obstruction. The regulations are more concerned that railings are erected for safety purposes rather than what they are like. Common sense will guide you in terms of the finish of the handrail. e.g. If it is wooden it must be sanded smooth and properly finish for longevity. If it is metal, the same applies, though you will also have to rustproof the metal.

  25. David Lee says:

    Good Afternoon,
    I want to install a handrail on the exterior stairwell of my sectional title apartment, and I want to know what the building and safety standards are. Can you help please,
    Thanks and Regards,