Grasdak dakke are most susceptible than any other roof type to being set alight by lightning. For the protection of the public and property the South African National Standard 62305-3 was introduced in 2011.
SANS 62305-3: Protection against Lightning (gepubliseer in 2011) is afkomstig van 'n internasionale standaard, IEC 62305. Deel 3 handel oor fisiese skade to structures and life hazards. It is 100% relevant to geboue met grasdak dakke.
SANS 10400-Part P, Drainage, Plumbing, The Vital Role of Drainage and Plumbing in Ensuring Health, Safety, and Efficiency in Buildings Introduction: Drainage and plumbing constitute a critical aspect of building infrastructure, playing a crucial role in maintaining safety, health, and the efficient functioning of a property. While often hidden from view, the pipes responsible for…
Wenke vir Badkamerbergingstelsels Badkamerberging en werkoppervlaktes is twee aspekte van badkamerbeplanning wat dikwels afgeskeep word. Oorweeg jou behoeftes aan die begin, en jy sal beloon word met 'n badkamer wat nie net netjies en vaartbelyn lyk nie, maar wat ook meer doeltreffend funksioneer. 'n Miniatuur medisynekas of smal glasrak is gereeld ...
Die Wet op Beskermingsmaatreëls vir Behuisingsverbruikers 95 van 1998 Opgedateer 2008 – VERDUIDELIK 1. Doel van die HCPA 1. Die hoofdoel van die Wet op Beskerming van Behuisingsverbruikers is om beskerming aan behuisingsverbruikers te gee. Terselfdertyd het dit die NASIONALE HUISBOUERS REGISTRASIERAAD (NHBRC) geskep, wie se doel is om te staan vir die...
Bouregulasies Deel-U Vullisverwydering Deel-U van die SANS 10400 Vullisverwydering bepaal dat 'Enige gebou, behalwe 'n woonhuis' wat vullis in daardie gebou gegenereer het, 'voldoende' stoorareas vir vullishouers sal voorsien. Bo en behalwe dit moet die beplanning en gebou toegang vanaf die straat verskaf sodat die houers...
Landskap van jou tuin Ons het hierdie artikel in twee afdelings verdeel: > Landskap van jou tuin in fases – Deel 1 & Landskap van jou tuin in fases – Deel 2 Die rede hiervoor is omdat wanneer jy 'n nuwe huis bou, begin om jou tuin van voor af te landskap is 'n enorme taak. Plante moet...
Hier is 'n klassieke filmsnit oor hoe om 'n huis te bou. Hierdie hoe om 'n huisfilmsnit te bou wat in 1946 gemaak is, is 'n moet-kyk vir enigiemand wat dit oorweeg om enige soort bouwerk te doen. Al is dit soveel jare gelede gemaak, het die proses min of meer dieselfde gebly….
Maak 'n opvolg-bydrae
44 Kommentaar
Ons het 'n weerligafleier met 'n effense buiging in. Hoeveel van 'n probleem hou dit vir versekering in?
Was daar enige wysigings aan die wet sedert 2018 rakende die aardingstelsel?
Dankie
How tall should a mast be and how often should these be inspected, legally?
According to Council any thatch structure (or indeed any structure with a roof on including garden sheds) needs plans irrespective of whether it is enclosed or not. It will need to be sprayed inside and out with a fire retardant and I have just been refused insurance as the lapa on the property does not have a lightning rod installed… Claire (Blue Designs)
Aangesien hierdie reëls van 2011 af is, doen hulle dit nie, alhoewel dit in jou belang is om te verseker dat die huis veilig is.
Alle lapas toe of oop benodig planne. As daar geen weerligpaal is nie, kry jy nie versekering nie
Hoe is hierdie nuwe regulasies van toepassing op 'n bestaande huis (meer as 25 jaar oud) wat 'n behandelde grasdak het?
'n Lapa is gewoonlik oopsy, dus vereis dalk nie planne nie. 'n Grasdakkamer is 'n struktuur wat planne SAL vereis.
kan lapa volledig omhein word deur gepleisterde mure met vensters en deure? wat is die verskil tussen lapa- en grasdakkamer?
Jou probleem is dat die balk- en kapvereistes vir die twee tipes dak verskil. Kontak dalk die vervaardigers van Chromadek vir kontrakteurverwysings.
Hallo, wonder net of jy ooit hierdie omskakeling gedoen het? Ek wil dieselfde doen maar kan niemand kry wat dit suksesvol gedoen het nie . Is daar enige betroubare dakkontrakteurs wat dit selfs sal aanvat ..? Ek wil van grasdak na chromadek geriffel omskakel deur die bestaande balke te gebruik, sal jy enige raad hê?
Brent, SANS 10313, 2010: Beskerming teen weerlig – Fisiese skade aan strukture en lewensgevaar, bespreek weerligbeskermingstelsels (LPS). Hierdie standaard definieer 'n LPS-ontwerper as "a
persoon wat bevoeg is om die LPS te ontwerp, te bou en te toets vir voldoening aan hierdie standaard”; en 'n LPS-installeerder as "'n persoon wat bevoeg is om 'n LPS te installeer, te bou en te toets vir voldoening aan hierdie standaard". Dit beteken die persoon moet opgelei en gekwalifiseer wees om óf 'n LPS te ontwerp, te bou en te toets en/of te installeer, kontrakteer en toets. Dus kan 'n grasdakbouer dalk AS hy die kwalifikasie het. Dit is soos om te vra of 'n boukontrakteur toegelaat word om elektrisiteit en/of loodgieterswerk te installeer. Die antwoord sal slegs wees as die kontrakteur 'n gekwalifiseerde en geregistreerde elektrisiën en/of loodgieter is (wat nie die norm is nie).

Brent is ongelukkig nie in 'n posisie om maatskappye aan te beveel nie.
Watter gras?
elektriese verbindings moet 'n meter van die gras af wees, tensy dit brandvaste toerusting is<<<<< <please comment if that is correct
Hi, ek is opsoek na installeerders van LPS in Pretoria. Weens 'n lekkende dak moes ek my hele grasdak herontwerp en vervang. Die bouer het egter my bestaande LPS verwyder en het nou aangedui dat hy dit nie kan vervang nie aangesien hy nie gekwalifiseer is om die stelsel te installeer nie. word grasdakbouers toegelaat om dit te doen?
Hi,
Ek was onlangs genoodsaak om my grasdak op te knap en te herbou aangesien die vorige eienaars die dak erg verwaarloos het. Die huidige bouer is gevra om my LPS te verwyder en dit iewers anders op die eiendom te plaas. Hy het nou aanspraak gemaak op onkunde en my sonder 'n LPS op my eiendom gelaat. Rig my asseblief na Pretoria-gebaseerde maatskappye wat kan help met die installering van die LPS by my eiendom aangesien 95% van die werklike huis nog grasdak is.
SANS 10407 handel oor “Thatch Roof Construction” en enige grasdak moet aan hierdie standaarde voldoen. Die dak moet deur 'n "bevoegde persoon" ontwerp word, die konstruksie moet deur hierdie persoon geïnspekteer word en as die dak aan die standaarde voldoen en korrek gebou is, sal hulle 'n COC (Sertifikaat van Voldoening) uitreik en dit sou voorsien gewees het aan die plaaslike raad se gebou-inspekteur voordat hulle 'n okkupasiesertifikaat uitreik.
Onderwerp:
SANS 10407
Boodskap:
Hi,
Kan jy my asseblief adviseer oor die vorm wat die strukturele ingenieur
moet afteken (die hele proses om die sertifikaat na te bring
gevolgtrekking) ingevolge SANS 10407, was die koper van die eiendom
baie spesifiek oor die SANS 10407-sertifikaat en verslag.
Enige hulp sal baie waardeer word.
Vriendelike groete,
Bianca Scott
In Huis Regsadviseur
Lees ons pos: grenslyne-mure-heinings Maar let op dat elke munisipaliteit 'n soneringskema vir elke voorstad het en elke eiendom sal anders wees. Gaan met jou plaaslike beplanningsafdeling.
Hallo, wat is die afstandvereistes vir die bou van 'n lapa? Dankie by voorbaat.
Groete.
Deel L van SANS 10400, Dakke verklaar: Grasdak moet aan die materiaalvereistes van SANS 10407 voldoen en geïnstalleer word in ooreenstemming met die vereistes van SANS 10407. Ek het nie toegang tot hierdie Standaard nie so weet nie of daar sprake is van 'n brandvertragersertifikaat nie, en of daar is 'n vereiste in terme daarvan dat dit hernu moet word. Deel T van SANS 10400, Vuur beskerming verklaar:
“4.12.2 Grasdakke
4.12.2.1 Die veiligheidsafstande afgelei van 4.2 sal, nieteenstaande die besettingsklasse gegee in tabel 2, gebaseer wees op 'n hoë brandlading waar die grasdak onbehandel is en waarde A in die formule gebaseer sal word op die fasadearea van die dak. Waar die grasdak met 'n aanvaarbare brandvertragende stelsel behandel word, moet die veiligheidsafstande gebaseer wees op die volgende brandladings:..."
wat impliseer dat 'n brandvertragende stelsel nie verpligtend is nie.
Ek is jammer ek kan nie meer behulpsaam wees nie. Jou plaaslike owerheid het dalk meer inligting, of 'n maatskappy wat spesialiseer in grasdakke.
Hallo Penny. ons het 'n aanbod om in te koop op 'n grasdakhuis gemaak. Kan jy asseblief adviseer oor die volgende saak, of stuur vir my die kontakbesonderhede van 'n persoon wat my kan help.
Moet die woning by oordrag 'n Brandvertragersertifikaat hê wat nog binne die beskermingstydperk is? Of kan hulle die eiendom verkoop sonder dat die woning deur 'n brandvertrager beskerm word?
SANS 10400 dek nie weerligafleiers nie, wat 'n baie gespesialiseerde veld is. Ek stel voor dat u een van die kondukteurinstallasiemaatskappye kontak wat u betroubare leiding behoort te gee.
hi.ek het 'n 4×3 m grasdak lapa.dit is 3,5 meter van my hoofhuis af en langs die grensmuur. benodig ek 'n weerligpaal of is brandvertragend genoeg. stuur asseblief jou antwoord na my e-posadres
Vriendelike groete
Neem asseblief kennis dat bouregulasies.co.za nie die maatskappy hierbo onderskryf nie; ons gee bloot inligting deur.
Hi
Ons maatskappy: Nimbus: Weerligbeskerming-SA doen wel inspeksies en instandhouding op bestaande LPS. Ons is gebaseer in JHB maar kan na Witbank uitkom.
Kontak: victor@exoveld.co.za
Hallo John, As jou grasdak-lapa binne 4,5m van enige grens of binne 9m van enige ander gebou op dieselfde eiendom is, word jy volgens wet verplig om Fire Protect sowel as 'n Rasionele Ontwerp (Brandontwerp) te verkry wat uitgereik is deur 'n " bevoegde persoon” in daardie veld. Voordat jy dit doen, moet jy seker maak dat die brandvertrager wat gebruik word deur die SABS en die munisipaliteite goedgekeur is. Jy loop die risiko dat jou versekering jou nie dek as dit nie gedoen word nie.
Hallo Nihan, in 2011 is die nuwe SANS 62305-3 bekendgestel en daar was dalk 'n verandering sedert jou goedkeuring 10 jaar gelede. Ons werk hoofsaaklik met SANS 10400, maar as jy die Elektriese Kontrakteursvereniging kontak, hanteer hulle dit elke dag: ecasa Ek sal jou aanraai om dit vir jou versekering te laat doen.
Kontak 'n maatskappy wat weerligstokke verskaf. As joune geroes is, kan jy dit dalk met 'n anti-roes produk bedek of op 'n ander manier laat behandel. Ek weet regtig nie. Vra eerder die mense wat in hierdie veld spesialiseer.
Hi,
Ons het 5 jaar gelede 'n grasdakhuis gekoop wat 3 weerligstawe het. Wat ek graag wil weet id hoe weet ek of hulle op standaard is? Hulle lyk geroes, is daar iets wat gedoen kan word om die roes reg te maak? Ek is in Witbank, wie kan ek kontak vir sulke hulp.
Hallo Elena, Die SANS10400 dek nie weerligafleiers nie, eerder die Nasionale Standaard IEC 62305 dek dit en is 'n gespesialiseerde veld. Ek stel voor dat u een van die kondukteurinstallasiemaatskappye kontak wat u leiding behoort te gee
Hi,
Ek beplan uitbreidings aan my grasdakhuis. Hoe naby aan my weerligafleier kan ek gaan?
Iemand het vir my gesê dat weerlig preotectors voorheen 20 Ohm was en nou moet dit 10 Ohm wees, want die weerlig het mettertyd meer intens geword. Enige waarheid daarin? Ek het geen kommunikasie van my huisversekeraar gehad nie. Nie 'n kenner nie, maar dit klink of die diensverskaffer onderduimse taktiek probeer om my R2K te spandeer om ons beligtingsbeskermer te "opgradeer" wat SABS goedgekeur is toe ons die huis 10 jaar gelede gekoop het. Enige raad sal waardeer word. Dankie.
Hallo Penny, ons kompleks het onlangs 'n soort brandinspeksie gehad en nou is ek meegedeel dat die lapa in my tuin 'n brandvertrager moet aanbring, is daar 'n bouregulasie of wet wat bepaal dat ek dit MOET laat doen? dit was in die eiendom toe ek ingetrek het en is nou so 8 jaar oud.
Pieter, Daar is inligting oor hierdie bladsy.
As 'n grasdak met gewels gebou word, sonder heupe, valleie of dakvensters, moet dit 'n helling van 45 grade hê, en 'n duidelike span wat nie meer as 6 m is nie.
Wat is die minimum helling vir 'n grasdak
Hallo Jaco,
Ek het 'n "Good Thatching Guide" deur die WNNR opgelaai wat jy op ons ander webwerf hier kan aflaai: ownerbuilding.co.za/document-downloads Registreer net (gratis) en jy sal die aflaaiskakel op daardie bladsy sien. Ek hoop dit help 🙂
Wat is regulasie met betrekking tot 'n grasdak wat aan 'n huis/struktuur vasgemaak is?
Ryno, jy moet met 'n dakkontrakteur praat. Die spesifikasies vir grasdak en IBR verskil heelwat. Jy moet seker wees dat alles wat die grasdak op die oomblik ondersteun, die nuwe dakbedekking sal kan ondersteun. Ek weet nie in watter toestand jou grasdak is nie, maar as ek 'n huis met 'n half ordentlike grasdak gehad het, sou ek dit laat herstel het.
Hi Penny, ek wil 'n grasdak met IBR vervang, dink jy is dit 'n goeie idee? Met watter ander materiaal sal jy aanbeveel om 'n grasdak mee te vervang?
Dankie
R
Ek het geen kennis van enige nie, maar het 'n websoektog gedoen. Surgetek het 'n tak in KZN.
Daar is 'n paar gelys hier, insluitend verskeie in Pinetown.
Hier is nog een in Pinetown.
Maak net dubbel seker dat hulle wel ingevolge die wet bevoeg is om jou te adviseer.
In die vorm wat die Weerlig beskerming stelsel installasie veiligheidsverslag in SANS 10313: 2010, sê dit “Ek/Ons, synde die persoon(e) verantwoordelik vir die ontwerp a, installasie a, inspeksie a, toetsing a, van die beligtingbeskermingstelsel (LPS), is bevoeg om te sertifiseer dat die LPS voldoen aan die vereistes van SANS 10313.” Maar dit spesifiseer nie wat hierdie “bevoegdheid” vereis nie – bv. die opleiding wat die persoon gehad het.
Hallo pennie,
Dankie, ek woon in Pinetown KZN, het jy 'n kontakmaatskappy wat ek kan bel?
Groete
Jeff Niemann
Jeff, ons is nie toegerus om oor hierdie tipe ding te adviseer nie. Jy moet waarskynlik 'n weerligbeskermingstelsel (LPS)-ontwerper of installeerder raadpleeg wat 'n "persoon is wat bevoeg is om die LPS te ontwerp, te bou en te toets vir voldoening aan" SANS 10313 (2010): Beskerming teen weerlig – Fisiese skade aan strukture en lewensgevaar. Ander standaarde waarna jy dalk moet kyk, sluit in alle dele van SANS 62305 & SANS 1063, aardstawe, koppelaars en verbindings. Aan die einde van die dag is weerlig gevaarlik in alle vorme.
Hallo, ek het 'n aluminiumpaal geïnstalleer wat 5m bokant my dak strek om sekuriteitskameras te huisves. Die paal is aan die muur van die hoofgebou vasgebout en rus op die grond. Ons het 'n paar stakings in ons area gehad. Is dit gevaarlik of kan ek dit net met 'n kabel en 'n koperstaaf aard?
Laat weet my asseblief want ek wil nie 'n probleem hê nie.
Dankie en groete
Jeff Niemann
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
Ons het 'n weerligafleier met 'n effense buiging in. Hoeveel van 'n probleem hou dit vir versekering in?
Was daar enige wysigings aan die wet sedert 2018 rakende die aardingstelsel?
Dankie
How tall should a mast be and how often should these be inspected, legally?
According to Council any thatch structure (or indeed any structure with a roof on including garden sheds) needs plans irrespective of whether it is enclosed or not. It will need to be sprayed inside and out with a fire retardant and I have just been refused insurance as the lapa on the property does not have a lightning rod installed… Claire (Blue Designs)
Aangesien hierdie reëls van 2011 af is, doen hulle dit nie, alhoewel dit in jou belang is om te verseker dat die huis veilig is.
Alle lapas toe of oop benodig planne. As daar geen weerligpaal is nie, kry jy nie versekering nie
Hoe is hierdie nuwe regulasies van toepassing op 'n bestaande huis (meer as 25 jaar oud) wat 'n behandelde grasdak het?
'n Lapa is gewoonlik oopsy, dus vereis dalk nie planne nie. 'n Grasdakkamer is 'n struktuur wat planne SAL vereis.
kan lapa volledig omhein word deur gepleisterde mure met vensters en deure? wat is die verskil tussen lapa- en grasdakkamer?
Jou probleem is dat die balk- en kapvereistes vir die twee tipes dak verskil. Kontak dalk die vervaardigers van Chromadek vir kontrakteurverwysings.
Hallo, wonder net of jy ooit hierdie omskakeling gedoen het? Ek wil dieselfde doen maar kan niemand kry wat dit suksesvol gedoen het nie . Is daar enige betroubare dakkontrakteurs wat dit selfs sal aanvat ..? Ek wil van grasdak na chromadek geriffel omskakel deur die bestaande balke te gebruik, sal jy enige raad hê?
Brent, SANS 10313, 2010: Beskerming teen weerlig – Fisiese skade aan strukture en lewensgevaar, bespreek weerligbeskermingstelsels (LPS). Hierdie standaard definieer 'n LPS-ontwerper as "a
persoon wat bevoeg is om die LPS te ontwerp, te bou en te toets vir voldoening aan hierdie standaard”; en 'n LPS-installeerder as "'n persoon wat bevoeg is om 'n LPS te installeer, te bou en te toets vir voldoening aan hierdie standaard". Dit beteken die persoon moet opgelei en gekwalifiseer wees om óf 'n LPS te ontwerp, te bou en te toets en/of te installeer, kontrakteer en toets. Dus kan 'n grasdakbouer dalk AS hy die kwalifikasie het. Dit is soos om te vra of 'n boukontrakteur toegelaat word om elektrisiteit en/of loodgieterswerk te installeer. Die antwoord sal slegs wees as die kontrakteur 'n gekwalifiseerde en geregistreerde elektrisiën en/of loodgieter is (wat nie die norm is nie).

Brent is ongelukkig nie in 'n posisie om maatskappye aan te beveel nie.
Watter gras?
elektriese verbindings moet 'n meter van die gras af wees, tensy dit brandvaste toerusting is<<<<< <please comment if that is correct
Hi, ek is opsoek na installeerders van LPS in Pretoria. Weens 'n lekkende dak moes ek my hele grasdak herontwerp en vervang. Die bouer het egter my bestaande LPS verwyder en het nou aangedui dat hy dit nie kan vervang nie aangesien hy nie gekwalifiseer is om die stelsel te installeer nie. word grasdakbouers toegelaat om dit te doen?
Hi,
Ek was onlangs genoodsaak om my grasdak op te knap en te herbou aangesien die vorige eienaars die dak erg verwaarloos het. Die huidige bouer is gevra om my LPS te verwyder en dit iewers anders op die eiendom te plaas. Hy het nou aanspraak gemaak op onkunde en my sonder 'n LPS op my eiendom gelaat. Rig my asseblief na Pretoria-gebaseerde maatskappye wat kan help met die installering van die LPS by my eiendom aangesien 95% van die werklike huis nog grasdak is.
SANS 10407 handel oor “Thatch Roof Construction” en enige grasdak moet aan hierdie standaarde voldoen. Die dak moet deur 'n "bevoegde persoon" ontwerp word, die konstruksie moet deur hierdie persoon geïnspekteer word en as die dak aan die standaarde voldoen en korrek gebou is, sal hulle 'n COC (Sertifikaat van Voldoening) uitreik en dit sou voorsien gewees het aan die plaaslike raad se gebou-inspekteur voordat hulle 'n okkupasiesertifikaat uitreik.
Onderwerp:
SANS 10407
Boodskap:
Hi,
Kan jy my asseblief adviseer oor die vorm wat die strukturele ingenieur
moet afteken (die hele proses om die sertifikaat na te bring
gevolgtrekking) ingevolge SANS 10407, was die koper van die eiendom
baie spesifiek oor die SANS 10407-sertifikaat en verslag.
Enige hulp sal baie waardeer word.
Vriendelike groete,
Bianca Scott
In Huis Regsadviseur
Lees ons pos: grenslyne-mure-heinings Maar let op dat elke munisipaliteit 'n soneringskema vir elke voorstad het en elke eiendom sal anders wees. Gaan met jou plaaslike beplanningsafdeling.
Hallo, wat is die afstandvereistes vir die bou van 'n lapa? Dankie by voorbaat.
Groete.
Deel L van SANS 10400, Dakke verklaar: Grasdak moet aan die materiaalvereistes van SANS 10407 voldoen en geïnstalleer word in ooreenstemming met die vereistes van SANS 10407. Ek het nie toegang tot hierdie Standaard nie so weet nie of daar sprake is van 'n brandvertragersertifikaat nie, en of daar is 'n vereiste in terme daarvan dat dit hernu moet word. Deel T van SANS 10400, Vuur beskerming verklaar:
“4.12.2 Grasdakke
4.12.2.1 Die veiligheidsafstande afgelei van 4.2 sal, nieteenstaande die besettingsklasse gegee in tabel 2, gebaseer wees op 'n hoë brandlading waar die grasdak onbehandel is en waarde A in die formule gebaseer sal word op die fasadearea van die dak. Waar die grasdak met 'n aanvaarbare brandvertragende stelsel behandel word, moet die veiligheidsafstande gebaseer wees op die volgende brandladings:..."
wat impliseer dat 'n brandvertragende stelsel nie verpligtend is nie.
Ek is jammer ek kan nie meer behulpsaam wees nie. Jou plaaslike owerheid het dalk meer inligting, of 'n maatskappy wat spesialiseer in grasdakke.
Hallo Penny. ons het 'n aanbod om in te koop op 'n grasdakhuis gemaak. Kan jy asseblief adviseer oor die volgende saak, of stuur vir my die kontakbesonderhede van 'n persoon wat my kan help.
Moet die woning by oordrag 'n Brandvertragersertifikaat hê wat nog binne die beskermingstydperk is? Of kan hulle die eiendom verkoop sonder dat die woning deur 'n brandvertrager beskerm word?
SANS 10400 dek nie weerligafleiers nie, wat 'n baie gespesialiseerde veld is. Ek stel voor dat u een van die kondukteurinstallasiemaatskappye kontak wat u betroubare leiding behoort te gee.
hi.ek het 'n 4×3 m grasdak lapa.dit is 3,5 meter van my hoofhuis af en langs die grensmuur. benodig ek 'n weerligpaal of is brandvertragend genoeg. stuur asseblief jou antwoord na my e-posadres
Vriendelike groete
Neem asseblief kennis dat bouregulasies.co.za nie die maatskappy hierbo onderskryf nie; ons gee bloot inligting deur.
Hi
Ons maatskappy: Nimbus: Weerligbeskerming-SA doen wel inspeksies en instandhouding op bestaande LPS. Ons is gebaseer in JHB maar kan na Witbank uitkom.
Kontak: victor@exoveld.co.za
Hallo John, As jou grasdak-lapa binne 4,5m van enige grens of binne 9m van enige ander gebou op dieselfde eiendom is, word jy volgens wet verplig om Fire Protect sowel as 'n Rasionele Ontwerp (Brandontwerp) te verkry wat uitgereik is deur 'n " bevoegde persoon” in daardie veld. Voordat jy dit doen, moet jy seker maak dat die brandvertrager wat gebruik word deur die SABS en die munisipaliteite goedgekeur is. Jy loop die risiko dat jou versekering jou nie dek as dit nie gedoen word nie.
Hallo Nihan, in 2011 is die nuwe SANS 62305-3 bekendgestel en daar was dalk 'n verandering sedert jou goedkeuring 10 jaar gelede. Ons werk hoofsaaklik met SANS 10400, maar as jy die Elektriese Kontrakteursvereniging kontak, hanteer hulle dit elke dag: ecasa Ek sal jou aanraai om dit vir jou versekering te laat doen.
Kontak 'n maatskappy wat weerligstokke verskaf. As joune geroes is, kan jy dit dalk met 'n anti-roes produk bedek of op 'n ander manier laat behandel. Ek weet regtig nie. Vra eerder die mense wat in hierdie veld spesialiseer.
Hi,
Ons het 5 jaar gelede 'n grasdakhuis gekoop wat 3 weerligstawe het. Wat ek graag wil weet id hoe weet ek of hulle op standaard is? Hulle lyk geroes, is daar iets wat gedoen kan word om die roes reg te maak? Ek is in Witbank, wie kan ek kontak vir sulke hulp.
Hallo Elena, Die SANS10400 dek nie weerligafleiers nie, eerder die Nasionale Standaard IEC 62305 dek dit en is 'n gespesialiseerde veld. Ek stel voor dat u een van die kondukteurinstallasiemaatskappye kontak wat u leiding behoort te gee
Hi,
Ek beplan uitbreidings aan my grasdakhuis. Hoe naby aan my weerligafleier kan ek gaan?
Iemand het vir my gesê dat weerlig preotectors voorheen 20 Ohm was en nou moet dit 10 Ohm wees, want die weerlig het mettertyd meer intens geword. Enige waarheid daarin? Ek het geen kommunikasie van my huisversekeraar gehad nie. Nie 'n kenner nie, maar dit klink of die diensverskaffer onderduimse taktiek probeer om my R2K te spandeer om ons beligtingsbeskermer te "opgradeer" wat SABS goedgekeur is toe ons die huis 10 jaar gelede gekoop het. Enige raad sal waardeer word. Dankie.
Hallo Penny, ons kompleks het onlangs 'n soort brandinspeksie gehad en nou is ek meegedeel dat die lapa in my tuin 'n brandvertrager moet aanbring, is daar 'n bouregulasie of wet wat bepaal dat ek dit MOET laat doen? dit was in die eiendom toe ek ingetrek het en is nou so 8 jaar oud.
Pieter, Daar is inligting oor hierdie bladsy.
As 'n grasdak met gewels gebou word, sonder heupe, valleie of dakvensters, moet dit 'n helling van 45 grade hê, en 'n duidelike span wat nie meer as 6 m is nie.
Wat is die minimum helling vir 'n grasdak
Hallo Jaco,
Ek het 'n "Good Thatching Guide" deur die WNNR opgelaai wat jy op ons ander webwerf hier kan aflaai: ownerbuilding.co.za/document-downloads Registreer net (gratis) en jy sal die aflaaiskakel op daardie bladsy sien. Ek hoop dit help 🙂
Wat is regulasie met betrekking tot 'n grasdak wat aan 'n huis/struktuur vasgemaak is?
Ryno, jy moet met 'n dakkontrakteur praat. Die spesifikasies vir grasdak en IBR verskil heelwat. Jy moet seker wees dat alles wat die grasdak op die oomblik ondersteun, die nuwe dakbedekking sal kan ondersteun. Ek weet nie in watter toestand jou grasdak is nie, maar as ek 'n huis met 'n half ordentlike grasdak gehad het, sou ek dit laat herstel het.
Hi Penny, ek wil 'n grasdak met IBR vervang, dink jy is dit 'n goeie idee? Met watter ander materiaal sal jy aanbeveel om 'n grasdak mee te vervang?
Dankie
R
Ek het geen kennis van enige nie, maar het 'n websoektog gedoen.
Surgetek het 'n tak in KZN.
Daar is 'n paar gelys hier, insluitend verskeie in Pinetown.
Hier is nog een in Pinetown.
Maak net dubbel seker dat hulle wel ingevolge die wet bevoeg is om jou te adviseer.
In die vorm wat die Weerlig beskerming stelsel installasie veiligheidsverslag in SANS 10313: 2010, sê dit “Ek/Ons, synde die persoon(e) verantwoordelik vir die ontwerp a, installasie a, inspeksie a, toetsing a, van die beligtingbeskermingstelsel (LPS), is bevoeg om te sertifiseer dat die LPS voldoen aan die vereistes van SANS 10313.” Maar dit spesifiseer nie wat hierdie “bevoegdheid” vereis nie – bv. die opleiding wat die persoon gehad het.
Hallo pennie,
Dankie, ek woon in Pinetown KZN, het jy 'n kontakmaatskappy wat ek kan bel?
Groete
Jeff Niemann
Jeff, ons is nie toegerus om oor hierdie tipe ding te adviseer nie. Jy moet waarskynlik 'n weerligbeskermingstelsel (LPS)-ontwerper of installeerder raadpleeg wat 'n "persoon is wat bevoeg is om die LPS te ontwerp, te bou en te toets vir voldoening aan" SANS 10313 (2010): Beskerming teen weerlig – Fisiese skade aan strukture en lewensgevaar. Ander standaarde waarna jy dalk moet kyk, sluit in alle dele van SANS 62305 & SANS 1063, aardstawe, koppelaars en verbindings. Aan die einde van die dag is weerlig gevaarlik in alle vorme.
Hallo, ek het 'n aluminiumpaal geïnstalleer wat 5m bokant my dak strek om sekuriteitskameras te huisves. Die paal is aan die muur van die hoofgebou vasgebout en rus op die grond. Ons het 'n paar stakings in ons area gehad. Is dit gevaarlik of kan ek dit net met 'n kabel en 'n koperstaaf aard?
Laat weet my asseblief want ek wil nie 'n probleem hê nie.
Dankie en groete
Jeff Niemann